Class information for: |
Basic class information |
| ID | Publications | Average number of references |
Avg. shr. active ref. in WoS |
|---|---|---|---|
| 16140 | 604 | 21.0 | 31% |
Classes in level above (level 2) |
| ID, lev. above |
Publications | Label for level above |
|---|---|---|
| 439 | 15579 | EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS//ENGINEERING STRUCTURES//MASONRY |
Terms with highest relevance score |
| Rank | Term | Type of term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
|---|---|---|---|---|---|---|
| 1 | PCI JOURNAL | Journal | 39 | 25% | 22% | 131 |
| 2 | SELF CENTERING | Author keyword | 29 | 52% | 6% | 39 |
| 3 | SELF CENTERING SYSTEMS | Author keyword | 27 | 92% | 2% | 11 |
| 4 | UNBONDED POST TENSIONING | Author keyword | 23 | 86% | 2% | 12 |
| 5 | PRECAST CONCRETE | Author keyword | 20 | 20% | 15% | 88 |
| 6 | DESIGN STRUCTURAL | Author keyword | 12 | 25% | 7% | 40 |
| 7 | CONTROLLED ROCKING | Author keyword | 11 | 100% | 1% | 6 |
| 8 | PRECAST | Author keyword | 10 | 26% | 5% | 33 |
| 9 | ROCKING WALL | Author keyword | 9 | 83% | 1% | 5 |
| 10 | DAMAGE AVOIDANCE DESIGN | Author keyword | 8 | 70% | 1% | 7 |
Web of Science journal categories |
Author Key Words |
| Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
LCSH search | Wikipedia search |
|---|---|---|---|---|---|---|---|
| 1 | SELF CENTERING | 29 | 52% | 6% | 39 | Search SELF+CENTERING | Search SELF+CENTERING |
| 2 | SELF CENTERING SYSTEMS | 27 | 92% | 2% | 11 | Search SELF+CENTERING+SYSTEMS | Search SELF+CENTERING+SYSTEMS |
| 3 | UNBONDED POST TENSIONING | 23 | 86% | 2% | 12 | Search UNBONDED+POST+TENSIONING | Search UNBONDED+POST+TENSIONING |
| 4 | PRECAST CONCRETE | 20 | 20% | 15% | 88 | Search PRECAST+CONCRETE | Search PRECAST+CONCRETE |
| 5 | DESIGN STRUCTURAL | 12 | 25% | 7% | 40 | Search DESIGN+STRUCTURAL | Search DESIGN+STRUCTURAL |
| 6 | CONTROLLED ROCKING | 11 | 100% | 1% | 6 | Search CONTROLLED+ROCKING | Search CONTROLLED+ROCKING |
| 7 | PRECAST | 10 | 26% | 5% | 33 | Search PRECAST | Search PRECAST |
| 8 | ROCKING WALL | 9 | 83% | 1% | 5 | Search ROCKING+WALL | Search ROCKING+WALL |
| 9 | DAMAGE AVOIDANCE DESIGN | 8 | 70% | 1% | 7 | Search DAMAGE+AVOIDANCE+DESIGN | Search DAMAGE+AVOIDANCE+DESIGN |
| 10 | DOUBLE TEES | 8 | 45% | 2% | 14 | Search DOUBLE+TEES | Search DOUBLE+TEES |
Key Words Plus |
| Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
|---|---|---|---|---|---|
| 1 | FRICTION DEVICES | 21 | 75% | 2% | 15 |
| 2 | LATERAL SYSTEM STRUCTURES | 14 | 100% | 1% | 7 |
| 3 | PARKING STRUCTURE DIAPHRAGMS | 14 | 100% | 1% | 7 |
| 4 | PERIMETER FRAMES | 14 | 100% | 1% | 7 |
| 5 | PRECAST CONCRETE WALLS | 13 | 80% | 1% | 8 |
| 6 | SEISMIC DESIGN METHODOLOGY | 11 | 100% | 1% | 6 |
| 7 | FLEXIBLE DIAPHRAGMS | 9 | 64% | 1% | 9 |
| 8 | DAMAGE AVOIDANCE | 8 | 100% | 1% | 5 |
| 9 | POSTTENSIONED STEEL CONNECTIONS | 7 | 67% | 1% | 6 |
| 10 | FLOOR DIAPHRAGMS | 6 | 80% | 1% | 4 |
Journals |
| Rank | Web of Science journal category | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
|---|---|---|---|---|---|
| 1 | PCI JOURNAL | 39 | 25% | 22% | 131 |
Reviews |
| Title | Publ. year | Cit. | Active references |
% act. ref. to same field |
|---|---|---|---|---|
| Historical overview of the PCI Journal and its contributions to the precast/prestressed concrete industry | 2007 | 0 | 56 | 57% |
Address terms |
| Rank | Address term | Relevance score (tfidf) |
Class's shr. of term's tot. occurrences |
Shr. of publ. in class containing term |
Num. of publ. in class |
|---|---|---|---|---|---|
| 1 | CONCRETE SERV | 3 | 100% | 0.5% | 3 |
| 2 | ATLSS | 2 | 11% | 2.2% | 13 |
| 3 | ADV TECHNOL LARGE STRUCT SYST ATLSS ENGN | 1 | 40% | 0.3% | 2 |
| 4 | GRP STRUCT ENGN | 1 | 19% | 0.7% | 4 |
| 5 | ADV TECHNOL BRIDGES INFRASTRUCT | 1 | 50% | 0.2% | 1 |
| 6 | BLUME EARTHQUAKE ENGN | 1 | 50% | 0.2% | 1 |
| 7 | BRIDGE STRUCT TEAM | 1 | 50% | 0.2% | 1 |
| 8 | CEN RED | 1 | 50% | 0.2% | 1 |
| 9 | CIVIL ARCHITECTURAL ENVIRONM LAND PLANNING E | 1 | 50% | 0.2% | 1 |
| 10 | CIVIL ENVIRON ARCHITECTURAL ENGN | 1 | 50% | 0.2% | 1 |
Related classes at same level (level 1) |
| Rank | Relatedness score | Related classes |
|---|---|---|
| 1 | 0.0000159441 | BUCKLING RESTRAINED BRACE//CONCENTRICALLY BRACED FRAMES//STEEL PLATE SHEAR WALLS |
| 2 | 0.0000156161 | BEAM COLUMN JOINTS//BEAM COLUMN JOINT//JOINTS JUNCTIONS |
| 3 | 0.0000136298 | OPTIMAL DAMPER PLACEMENT//SUPPLEMENTAL DAMPING//VISCOUS DAMPERS |
| 4 | 0.0000120906 | ROCKING//FOUNDATION UPLIFT//OVERTURNING |
| 5 | 0.0000109546 | INSULATED PANELS//SANDWICH WALL PANELS//CIVIL CONSTRUCT ENGN ARCHITECTURE |
| 6 | 0.0000105862 | EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS//PUSHOVER ANALYSIS//JOURNAL OF EARTHQUAKE ENGINEERING |
| 7 | 0.0000096756 | INFILLED FRAMES//MASONRY INFILL//MASONRY INFILLS |
| 8 | 0.0000089507 | CONCRETE COLUMNS//CONFINEMENT//CONFINED CONCRETE |
| 9 | 0.0000082470 | ACI STRUCTURAL JOURNAL//DEEP BEAMS//REINFORCED CONCRETE |
| 10 | 0.0000081953 | PCI JOURNAL//TRANSFER LENGTH//PRESTRESSED CONCRETE |