Class information for: |
Basic class information |
Class id | #P | Avg. number of references |
Database coverage of references |
---|---|---|---|
1962 | 5659 | 35.0 | 54% |
Hierarchy of classes |
The table includes all classes above and classes immediately below the current class. |
Cluster id | Level | Cluster label | #P |
---|---|---|---|
4 | 4 | ENVIRONMENTAL SCIENCES//GEOSCIENCES, MULTIDISCIPLINARY//METEOROLOGY & ATMOSPHERIC SCIENCES | 1766162 |
108 | 3 | AIR POLLUTION//TOXICOLOGY//PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH | 71534 |
1962 | 2 | MULTIPLE CHEMICAL SENSITIVITY//INDOOR AIR//SICK BUILDING SYNDROME | 5659 |
4896 | 1 | INDOOR CHEMISTRY//INDOOR AIR//INDOOR AIR QUALITY | 1706 |
5982 | 1 | FORMALDEHYDE//DNA PROTEIN CROSS LINKS//NASAL TOXICITY | 1548 |
10987 | 1 | SICK BUILDING SYNDROME//INDOOR AIR//INDOOR AIR QUALITY | 1018 |
12447 | 1 | MULTIPLE CHEMICAL SENSITIVITY//IDIOPATHIC ENVIRONMENTAL INTOLERANCE//CHEMICAL SENSITIVITY | 905 |
23812 | 1 | SENSORY IRRITATION//CHEMOSENSORY PERCEPT//NASAL PUNGENCY | 334 |
31761 | 1 | MASS PSYCHOGENIC ILLNESS//MASS HYSTERIA//MASS SOCIOGENIC ILLNESS | 148 |
Terms with highest relevance score |
rank | Term | termType | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|---|
1 | MULTIPLE CHEMICAL SENSITIVITY | authKW | 904662 | 4% | 81% | 206 |
2 | INDOOR AIR | journal | 488391 | 5% | 30% | 307 |
3 | SICK BUILDING SYNDROME | authKW | 443391 | 3% | 55% | 149 |
4 | FORMALDEHYDE | authKW | 410810 | 9% | 15% | 522 |
5 | INDOOR AIR QUALITY | authKW | 396398 | 6% | 23% | 319 |
6 | SENSORY IRRITATION | authKW | 273448 | 1% | 69% | 74 |
7 | IDIOPATHIC ENVIRONMENTAL INTOLERANCE | authKW | 170642 | 1% | 70% | 45 |
8 | ENVIRONMENTAL ILLNESS | authKW | 167789 | 1% | 66% | 47 |
9 | CHEMICAL SENSITIVITY | authKW | 165668 | 1% | 64% | 48 |
10 | INDOOR CHEMISTRY | authKW | 165182 | 1% | 88% | 35 |
Web of Science journal categories |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | Construction & Building Technology | 45299 | 15% | 1% | 862 |
2 | Toxicology | 26867 | 21% | 0% | 1188 |
3 | Public, Environmental & Occupational Health | 26387 | 28% | 0% | 1609 |
4 | Engineering, Environmental | 24001 | 17% | 1% | 949 |
5 | Environmental Sciences | 10720 | 22% | 0% | 1252 |
6 | Engineering, Civil | 2709 | 7% | 0% | 375 |
7 | Materials Science, Paper & Wood | 2135 | 2% | 0% | 136 |
8 | Allergy | 1994 | 3% | 0% | 168 |
9 | Meteorology & Atmospheric Sciences | 1793 | 6% | 0% | 321 |
10 | Medicine, Legal | 576 | 1% | 0% | 67 |
Address terms |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | CHEMOSENSORY PERCEPT | 160836 | 1% | 69% | 43 |
2 | INT INDOOR ENVIRONM ENERGY | 139384 | 1% | 32% | 82 |
3 | INDOOR ENVIRONM | 89791 | 1% | 29% | 57 |
4 | MAT ANAL INDOOR CHEM | 48698 | 0% | 53% | 17 |
5 | BLDG SCI | 46483 | 1% | 11% | 77 |
6 | DANISH CHEM SENSIT | 41488 | 0% | 77% | 10 |
7 | EXPOSURE ASSESSMENT BRANCH | 32378 | 0% | 24% | 25 |
8 | DANISH CHEM SENSITIV | 31379 | 0% | 73% | 8 |
9 | INDOOR ENVIRONM GRP | 31363 | 0% | 36% | 16 |
10 | MED SCI OCCUPAT ENVIRONM MED | 29686 | 1% | 15% | 36 |
Journals |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
---|---|---|---|---|---|
1 | INDOOR AIR | 488391 | 5% | 30% | 307 |
2 | INDOOR AND BUILT ENVIRONMENT | 63389 | 2% | 10% | 117 |
3 | BUILDING AND ENVIRONMENT | 51951 | 4% | 4% | 219 |
4 | INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 33022 | 0% | 44% | 14 |
5 | TOXICOLOGY AND INDUSTRIAL HEALTH | 25241 | 2% | 5% | 94 |
6 | INHALATION TOXICOLOGY | 18932 | 2% | 4% | 85 |
7 | ARCHIVES OF ENVIRONMENTAL HEALTH | 18903 | 1% | 5% | 74 |
8 | ATMOSPHERIC ENVIRONMENT | 16151 | 4% | 1% | 228 |
9 | INTERNATIONAL JOURNAL OF VENTILATION | 13870 | 0% | 10% | 26 |
10 | OCCUPATIONAL MEDICINE-STATE OF THE ART REVIEWS | 13027 | 1% | 6% | 42 |
Author Key Words |
Rank | Term | Chi square | Shr. of publ. in class containing term |
Class's shr. of term's tot. occurrences |
#P with term in class |
LCSH search | Wikipedia search |
---|---|---|---|---|---|---|---|
1 | MULTIPLE CHEMICAL SENSITIVITY | 904662 | 4% | 81% | 206 | Search MULTIPLE+CHEMICAL+SENSITIVITY | Search MULTIPLE+CHEMICAL+SENSITIVITY |
2 | SICK BUILDING SYNDROME | 443391 | 3% | 55% | 149 | Search SICK+BUILDING+SYNDROME | Search SICK+BUILDING+SYNDROME |
3 | FORMALDEHYDE | 410810 | 9% | 15% | 522 | Search FORMALDEHYDE | Search FORMALDEHYDE |
4 | INDOOR AIR QUALITY | 396398 | 6% | 23% | 319 | Search INDOOR+AIR+QUALITY | Search INDOOR+AIR+QUALITY |
5 | SENSORY IRRITATION | 273448 | 1% | 69% | 74 | Search SENSORY+IRRITATION | Search SENSORY+IRRITATION |
6 | IDIOPATHIC ENVIRONMENTAL INTOLERANCE | 170642 | 1% | 70% | 45 | Search IDIOPATHIC+ENVIRONMENTAL+INTOLERANCE | Search IDIOPATHIC+ENVIRONMENTAL+INTOLERANCE |
7 | ENVIRONMENTAL ILLNESS | 167789 | 1% | 66% | 47 | Search ENVIRONMENTAL+ILLNESS | Search ENVIRONMENTAL+ILLNESS |
8 | CHEMICAL SENSITIVITY | 165668 | 1% | 64% | 48 | Search CHEMICAL+SENSITIVITY | Search CHEMICAL+SENSITIVITY |
9 | INDOOR CHEMISTRY | 165182 | 1% | 88% | 35 | Search INDOOR+CHEMISTRY | Search INDOOR+CHEMISTRY |
10 | INDOOR AIR | 137310 | 3% | 16% | 155 | Search INDOOR+AIR | Search INDOOR+AIR |
Core articles |
The table includes core articles in the class. The following variables is taken into account for the relevance score of an article in a cluster c: (1) Number of references referring to publications in the class. (2) Share of total number of active references referring to publications in the class. (3) Age of the article. New articles get higher score than old articles. (4) Citation rate, normalized to year. |
Rank | Reference | # ref. in cl. |
Shr. of ref. in cl. |
Citations |
---|---|---|---|---|
1 | SALTHAMMER, T , MENTESE, S , MARUTZKY, R , (2010) FORMALDEHYDE IN THE INDOOR ENVIRONMENT.CHEMICAL REVIEWS. VOL. 110. ISSUE 4. P. 2536 -2572 | 168 | 54% | 276 |
2 | FADEYI, MO , (2015) OZONE IN INDOOR ENVIRONMENTS: RESEARCH PROGRESS IN THE PAST 15 YEARS.SUSTAINABLE CITIES AND SOCIETY. VOL. 18. ISSUE . P. 78 -94 | 151 | 86% | 1 |
3 | WESCHLER, CJ , (2011) CHEMISTRY IN INDOOR ENVIRONMENTS: 20 YEARS OF RESEARCH.INDOOR AIR. VOL. 21. ISSUE 3. P. 205 -218 | 154 | 66% | 59 |
4 | WOLKOFF, P , (2013) INDOOR AIR POLLUTANTS IN OFFICE ENVIRONMENTS: ASSESSMENT OF COMFORT, HEALTH, AND PERFORMANCE.INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH. VOL. 216. ISSUE 4. P. 371-394 | 165 | 55% | 48 |
5 | GOLDEN, R , (2011) IDENTIFYING AN INDOOR AIR EXPOSURE LIMIT FOR FORMALDEHYDE CONSIDERING BOTH IRRITATION AND CANCER HAZARDS.CRITICAL REVIEWS IN TOXICOLOGY. VOL. 41. ISSUE 8. P. 672 -721 | 114 | 81% | 43 |
6 | LIU, Z , YE, W , LITTLE, JC , (2013) PREDICTING EMISSIONS OF VOLATILE AND SEMIVOLATILE ORGANIC COMPOUNDS FROM BUILDING MATERIALS: A REVIEW.BUILDING AND ENVIRONMENT. VOL. 64. ISSUE . P. 7-25 | 91 | 86% | 30 |
7 | ZHANG, Y , XIONG, J , MO, J , GONG, M , CAO, J , (2016) UNDERSTANDING AND CONTROLLING AIRBORNE ORGANIC COMPOUNDS IN THE INDOOR ENVIRONMENT: MASS TRANSFER ANALYSIS AND APPLICATIONS.INDOOR AIR. VOL. 26. ISSUE 1. P. 39 -60 | 69 | 76% | 8 |
8 | NAYA, M , NAKANISHI, J , (2005) RISK ASSESSMENT OF FORMALDEHYDE FOR THE GENERAL POPULATION IN JAPAN.REGULATORY TOXICOLOGY AND PHARMACOLOGY. VOL. 43. ISSUE 3. P. 232-248 | 106 | 80% | 32 |
9 | LABARGE, AS , MCCAFFREY, RJ , (2000) MULTIPLE CHEMICAL SENSITIVITY: A REVIEW OF THE THEORETICAL AND RESEARCH LITERATURE.NEUROPSYCHOLOGY REVIEW. VOL. 10. ISSUE 4. P. 183 -211 | 120 | 80% | 42 |
10 | WOLKOFF, P , NIELSEN, GD , (2010) NON-CANCER EFFECTS OF FORMALDEHYDE AND RELEVANCE FOR SETTING AN INDOOR AIR GUIDELINE.ENVIRONMENT INTERNATIONAL. VOL. 36. ISSUE 7. P. 788-799 | 91 | 71% | 47 |
Classes with closest relation at Level 2 |