Skip to main content
To KTH's start page To KTH's start page

Fracture setting method could replace metal plates, with fewer complications

A bone with screws to hold it together, plus the polymer custom-made patch.
The alternative surgical method combines screws with a build-up of the composite material.
Published Jun 22, 2021

A new biocompatible polymer-based composite material could soon replace metal plates in treating difficult and unstable fractures. Developed at KTH Royal Institute of Technology in Stockholm, the newly-developed material is as strong as dental composites yet non-toxic.

The material and a surgical method, which were published in Advanced Functional Materials , will be used in clinical studies in 2023 and 2024, with a focus on hand fractures.

Michael Malkoch , professor of fibre and polymer technology at KTH, says that the material and method, which is called AdhFix, will enable customized plating for fixation of fractures with a more comfortable, less complicated recovery. Collarbone and rib fractures in particular are ideally suited for the proposed treatment, since such injuries are not easy to stabilize. 

Metal plates cannot be easily customized in shape, and they tend to adhere to soft tissue, resulting in debilitating complications, says Malkoch. For example, nearly 64 percent of finger fractures treated with metal plates result in mobility complications.

The alternative surgical method, AdhFix, combines screws with a build-up of the polymer/hydroxyapatite composite instead. The composite is shaped in situ before being rapidly cured on demand via high-energy visible-light-induced thiol–ene coupling chemistry.

Evaluations on human cadaver hands with proximal phalanx fractures show that AdhFix withstands the forces from finger flexing exercises. In models of in vivo femur fractures in rats, the methodology supported bone healing without degradation, adverse effects or soft-tissue adhesions.

“No fracture is the same as the other, this is one of the absolute advantages of the material,” says Malkoch. “A surgeon can tailor the fixation plate according to the patient's bone shape and the structure of the fracture. The hospital also does not have to store metal plates.”

Malkoch says the material and method also may be applied to veterinary care as well. Animals with metal plates are known to avoid going outdoors in cool temperatures because the metal conducts the cold differently than the KTH researchers’ composite.

The work was carried out together with RISE in Gothenburg and hand surgeons working at Karolinska Institutet and Södersjukhuset. Daniel Hutchinson , researcher in polymer and fibre technology at KTH, led the study.

Funding for the research was made possible by: Knut and Alice Wallenberg Foundation (grant nr. 2017.0300 and 2019.0002)

Peter Larsson/David Callahan

"Highly Customizable Bone Fracture Fixation through the Marriage of Composites and Screws",
Advanced Functional Materials, doi.org/10.1002/adfm.202105187

Page responsible:redaktion@kth.se
Belongs to: About KTH
Last changed: Jun 22, 2021